Calor Verde - Technical Information

Model
CV09
CV12
CV16
CV23s
CV30s
Heating capacity KW (air 26°,water 26°)
9
12
16
23
30
C.O.P. (air 26°,water 26°)
≥6.0
≥6.0
≥6.0
≥6.0
≥6.0
Heating capacity KW (air 15°,water 26°)
6.3
8.5
11
16
21
C.O.P. (air 15°,water 26°)
≥4.5
≥4.5
≥4.5
≥4.5
≥4.5
Advised pool volume m3 (with insulated pool cover) 30-40 40-60 50-80 80-110 100-150
Reduction of energy bill (compared with electric heater) 75-85% 75-85% 75-85% 75-85% 75-85%
Operating range- Air (c°) 0-43 0-43 0-43 0-43 0-43
Advised water flux m3/h 4-6 5-7 6.5-8.5 8-10 10-12
Rated power/ Max power Kw 1.4/1.8 1.8/2.4 2.4/3.1 3.8/5.6 4.5/6.3
Power supply 220-240V/1Ph/50Hz or 60Hz 380-415V/3Ph/50Hz or 60Hz
Heat Exchanger Titanium in PVC-U Tank
Rated current / Max current A 6.4/8.2 8.2/11.0 10.9/14.1 5.8/8.5 6.8/9.5
Compressor Rotary Rotary Rotary Scroll Scroll
Fan direction Horizontal
Noise level dB(A) ≤48 ≤48 ≤50 ≤56 ≤58
Water pipe in-out spec mm 50 50 50 50 50
Net dimension - LxWxH mm 930x350x550 1000x350x630 1000x380x730 1120x470x950 1180x470x950
Packing dimension - LxWxH mm 1025x380x595 1090x380x665 1100x440x790 1210x500x990 1260x500x990
Net weight / Gross weight Kg 52/57 66/70 85/93 127/137 150/160